Showing posts with label Induction machines. Show all posts
Showing posts with label Induction machines. Show all posts

Monday, April 18, 2011

Induction Machines-Performance

Induction Machines-Performance

  • In induction motor, the magnetizing current is much larger than the active current, so that the no-load power factor is low,0.1 or 0.25
  • If a load torque applied to the shaft, the active component of stator current increases and magnetizing current remains constant, the power factor is raised
  • The maximum effieciency ocurs roughly where the I2R losses in stator and rotor sum to ana amount equal to the no-load constant losses.
  • Usual reltio to maximum to full load torque is 2:1
  • Cage motors:
  • Motors with normal starting torque and current , having cages with low resistance and reactance, low full load slip, good efficiency and power factor
  • Motors with high starting torque and low starting current, using deep-bar rotor or double cage rotors.
  • Motors with high full load slip, using a comparatively high resistance cage , with large starting torque, low starting current and low efficiency. Used for fluctuating torque drives(punching machines)
  • Multispeed Motors:
  • variable-torque, power output proportional to square of speed-fans,centrifugal pumps
  • Constant torque, power output proportional to speed-conveyors,stokers, reciprocating compressors,printing presses
  • Inverse torque, power output rating constant-machine tools,laths,boring mills,drills,planners
  • Gear motors- high speed motors-conveyors,agitators,blowers and screens
  • A startor may either increase rotor resistance or decrease starting current in induction machine
  • The inclusion of rotor resistance will reduce the stator current at standstill and simultaneously raise its power factor.
  • The starting current of a cage motor can only be reduced by lowering the voltage applied to the stator
  • The output and torque for a given slip change as the square of the allied voltage and current reduces in proportionally
  • Direct online startor
  • For direct switching case, if TSC be the torque developed on short circuit at normal voltage with currents ISC then starting torque is TS = TSC and the starting current per phase is IS = ISC the ratio of starting to full load torque is TS/Tn=(ISC/In)2sn
  • Stator resistor startor:
  • The normal voltage per phase to the fraction x is applied to the termianls. The starting current is Is = xIsc and starting torque Ts = x2Tsc
  • The ratio of statig torque to full load torque is Ts/Tn = (Is/In)2sn = x2(Isc/In)2sn
  • Auto-trnasformer startor:
  • The auto-transformer starter is used to reduce the phase voltage to the fraction x of normal value. The starting current is Is = xIsc and starting torque Ts = x2Tsc
  • The ratio of statig torque to full load torque is Ts/Tn = (Is/In)2sn = x2(Isc/In)2sn
  • Star- Delta startor
  • A motor must be built to run normally with a mesh connected stator winding. At starting the winding is connected temporarily in star. The phase voltage is thus reduced to 1/√3 = 0.58 of normal.
  • The starting current per pahse is Is = 0.58Isc, the line current is (0.58)2Isc = 0.33Isc, the starting torque is one third of short circuit value.
  • the ratio to starting torque to full load torque is Ts/Tn = (1/3)(Isc/In)2sn
  • Cogging and Crawling:
  • If the number of stator slots S1 equal to the rotor slots S2, the machine may efuse to start at all, this is called cogging or teeth locking.
  • With other ratios S2/S1, the motor may exhibit a tendency to run stabnly at low speed (one-seventh of normal): this is called crawling.
  • The 5th harmonic r.m.f rotates agaonst the fundamental at one-fifth synchronous speed.
  • The 7th harmonic r.m.f rotates with the fundamental at one-seventh synchronous speed.
  • If the harmonic torques are sufficiently pronounced, the seventh harmonic may prevent the motor speed exceeding abiut one-seventh of normal, since the downward slope of the resultant torque at this speed is a stable running condition over the torque range between the maximum and minimum points. The motor therefore crawls.
  • If n1 is the synchronous speed of fundamental, and n the speed of the rotor, then the synchronous speed of the thirteenth harmonic is +n1/13, or relative to the rotor -(n1-n)/13. The rotor runs at a speed n, and so rotates its own thirteenth harmonic at a speed -(n1-n)/13+n relative to the stator. The sttor and rotor thirteenth harmonic fall into step when +n1/13 = -(n1-n)/13+n i.e. n= (1/7)n1. Thus the torque discontinuity at one seventh synchronous speed is here produced not by the seventh harmonic, but by the thirteen.

Induction Machines-Theory

Induction Machines-Theory

  • The induction motor consists of a fixed core, the stator, carrying a three phase winding in slots on its bore.
  • The stator winding is connected to the supply, and a uniform rotating magnetic filed is produced therein.
  • It works based on principle of Electro-magnetic interaction
  • Speed of the stator m.m.f is synchronous speed
  • The speed of rotation,n, of the rotor is less than the synchronous speed by a fraction,s known as the slip
  • A high ratio of resistance to reactance is desirable under starting conditions, but the resistance should be low for running near synchronous speed, the normal condition
  • The induction motor is a machine of substantially constant speed, and fills the same role as the plain shunt motor among the dc machines
  • The cage rotor is adaptable to any number of poles. whereas the slip-ring winding has to be made for one(or possibly two) definite values of p.
  • leakage flux is greater than transformer in induction machine due to its air gap
  • Power relations:
  • Power input to the stator per phase is P1 = V1I1cosØ1
  • Power delivered by transformer action to the rotor, P2
  • The mechanical power developed at the rotor, Pm = (1-s)P2
  • Rotor power loss is I22r2 = sP2 = s.rotor input
  • P2:Pm:I22r2 = 1:(1-s):s
  • If the rotor had no resistance it could develop no torque
  • condition for maximum torque is r2 = ±sx2
  • Slip values for different operations: If s is positive and between 0 and 1 : Motor, If s is negative and -1 to 0 : generator, If s greater than unity: braking
 




Solved Problems
1.A 220-V, three-phase, two-pole, 50-Hz induction motor is running at a slip of 5 percent. Find:
(a) The speed of the magnetic fields in revolutions per minute
(b) The speed of the rotor in revolutions per minute
(c) The slip speed of the rotor
(d) The rotor frequency in hertz

SOLUTION:

(a) The speed of the magnetic fields is

(b) The speed of the rotor is


(c) The slip speed of the rotor is


(d) The rotor frequency is



2.A three-phase, 60-Hz induction motor runs at 890 r/min at no load and at 840 r/min at full load.
(a) How many poles does this motor have?
(b) What is the slip at rated load?
(c) What is the speed at one-quarter of the rated load?
(d) What is the rotor’s electrical frequency at one-quarter of the rated load?
SOLUTION
(a) This machine has 8 poles, which produces a synchronous speed of

(b) The slip at rated load is


(c) The motor is operating in the linear region of its torque-speed curve, so the slip at ¼ load will be


The resulting speed is


(d) The electrical frequency at ¼ load is